Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 87 Warning: chmod() expects exactly 2 parameters, 3 given in /home/virtual/lib/view_data.php on line 88 Warning: fopen(/home/virtual/jikm/journal/upload/ip_log/ip_log_2024-07.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 95 Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 96 Measurement of Gastric Contractility of Awake Rats by Bowel Sounds Recorded through an Electronic Stethoscope in a Sound Insulation Box
| Home | E-Submission | Sitemap | Editorial Office |  
top_img
The Journal of Internal Korean Medicine > Volume 35(4); 2014 > Article
The Journal of Internal Korean Medicine 2014;35(4): 439-447.
차음상자와 전자청진기로 기록된 장음에 의해서 깨어 있는 흰쥐의 위수축력 측정
윤상협
경희대학교 한의과대학 비계내과학교실
Measurement of Gastric Contractility of Awake Rats by Bowel Sounds Recorded through an Electronic Stethoscope in a Sound Insulation Box
Sang-hyub Yoon
3rd Dept. of Internal Medicine, College of Korean Medicine, Kyung-Hee University
Correspondence  Sang-hyub Yoon ,Tel: 02-958-9142, Email: sandrock58@nate.com
  Published online: December 30, 2014.
ABSTRACT
Objectives:
The aim of this study was to investigate whether 1) variation of bowel sounds recorded stably through an electronic stethoscope in a sound insulation box can be related with that of gastric contraction and 2) if they are thus useful tool in the measurement of the gastric contractility in awake rats or not.

Methods:
Electrical potentials of both electronic stethoscope of bowel sound and force transducer were recorded simultaneously and continuously in the sound insulation box for the starting 30 min of basal state, and then 30 min of 0.2 ml normal saline administration, finally 30 min of 0.2 ml mosapride citrate solution (100 mg/Kg) in rats. Each motility index of normal saline or mosapride citrate treatment was presented with ratio against the basal state by using integrated electrical potentials.

Results:
A pattern of significance of gastric contractility between bowel sound and force transducer was showed analogously.

Conclusions:
The amplitude of bowel sounds recorded by the electronic stethoscope related with the intensity of gastric contractions. This confirms that a sound insulation box and electronic stethoscope are useful tools in the measurement of the gastric contractility of awake rats.
Key words: bowel sound, force transducer, gastric contractility, motility index
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
955
View
12
Download
Related article
Editorial Office
Dongguk University Ilsan Oriental Hospital
27, Dongguk-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 10326 Korea
TEL: +82-31-961-9046   FAX: +82-31-961-9049   E-mail: jikm.edit@gmail.com
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Society of Internal Korean Medicine.                 Developed in M2PI      |      Admin Login